Victron Orion-TR DC-DC Converter - 12 VDC TO 24 VDC - 10A Isolated [ORI122424110]
TMK-92885
- In stock, ready to ship
- Inventory on the way
Get it Between - Free Shipping on Orders Over $500.00
Orion-TR 12/24-10A (240W) Isolated DC-DC Converter
Isolated Model - separate in and out (-) leads
Remote On/Off Terminal
The remote on/off terminal eliminates the need for a high current switch in the input wiring. The remote on/off can be operated with a low power switch or for example the engine run/stop switch.
All Models Are Short Circuit Proof and Can Be Paralleled to Increase Output Current
An unlimited number of units can be connected in parallel.
High Temperature Protected
The output current will reduce at high ambient temperatures.
IP43 Protection
When installed with the screw terminals oriented downward.
Screw Terminals
No special tools are needed for installation.
Input Fuse (not replaceable)
On 12 V and 24 V input models only.
Adjustable Output Voltage
Not intended for battery charging (consider using an Orion-Tr Smart for battery charging).
Specifications:
- Input Voltage Range: 8-17 V
- Under Voltage Shut Down: 7 V
- Under Voltage Restart: 7.5 V
- Nominal Output Voltage: 12.2 V
- Output Voltage Adjust Range: 10-15 V
- Output Voltage Tolerance: +/- 0,2 V
- Output Noise: 2 mV rms
- Cont. Output Current at Nominal Output Voltage and 40 Degrees C: 10 A
- Maximum Output Current (10 S) at Nominal Output Voltage: 15 A
- Short Circuit Output Current: 25 A
- Cont. Output Power at 25 Degrees C: 280 W
- Cont. Output Power at 40 Degrees C: 240 W
- Efficiency: 88 %
- No Load Input Current (2): < 100 mA
- Current Consumption: < 200uA when disabled via its remote port
- Galvanic Isolation: 200 VDC between input, output, and case
- Operating Temperature Range: -20 to +55 Degrees C (derate 3 % per °C above 40 °C)
- Humidity: Max. 95 % non-condensing
- DC Connection: Screw terminals
- Maximum Cable Cross-Section: 16 mm² AWG6
- Weight: 1.3 kg (3 lb)
- Dimensions (H x W x D): 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)
- Safety Standards: EN 60950
- Emission: EN 61000-6-3, EN 55014-1
- Immunity Standards: EN 61000-6-2, EN 61000-6-1, EN 55014-2
- Automotive Directive Standards: ECE R10-5
Quick Guide (pdf)
Ship any number of items to any lower 48 states (Continental US) Shipping Charges (Per Session Total Value) may apply :
Rate Name | Condition | Fee |
Alpha |
$0.01 To $50 |
$09.95 |
Beta |
$50.01 To $150 |
$08.50 |
Gamma |
$150.01 To $300 |
$06.90 |
Delta |
$300.01 To $499.99 |
$04.90 |
Epsilon | $500 & Up | $0.00 |
Shipping Delivery Time:
- Cutoff Time: 10:00 PM (GMT-05:00) Eastern Standard Time (New York)
- Handling Time: 02-03 Business Days.
- Transit Time: 05-07 Business Days.
- We may use UPS, FedEx, or USPS shipping services.
- The day of shipment does not count as a transit day Offer is valid in the continental US (lower 48 states) only.
- The offer does not include 'Alaska' 'Hawaii